1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with

1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with

1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with ,Benclimate,Construction & Real Estate,HVAC Systems & Parts
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
Benclimate
Model Number:
ZJXRA25/2a
Type:
Ventilation
Heating capacity of heat pump system:
2480 W
Cooling capacity of heat pump system:
2350 W
Electrical heater power:
1200 W
Compressor type:
Rotory
Refrigerant:
R410a
Fan Type:
EC centrifugal fan
Airflow:
480/320/160 m3/h
External static pressure:
130 Pa
Filter class:
G4+F7+H10
Diameter of air vents:
200 mm
Supply Ability
Supply Ability:
3000 Set/Sets per Month optional
Packaging & Delivery
Packaging Details
Carton in laid with polystyrene, 5-6 cartons to a pallet
Port
Tianjin
Lead Time :
30days

Specifications

1.Energy recovery airflow is 480/320/160m3/h
2.Three speed EC motor fan
3.Fresh air filter class is G4+F7+H10
4.220-240V

 

 

Energy saving principle

1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with heat pump

Working principle of  the 1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with heat pump  
It can expel the stale air indoor out of room, meanwhile supplying the fresh air outside into the room, by using the advanced heat/energy recovering technology, the energy can exchange taking advantage of the difference of the temperature and humidity between indoor and outdoor air. By this means, it can not only smooth away the problem of indoor pollution, but also saving energy.

 

The main features : 

1. Heating capacity of heat pump system 2480 W

2. Cooling capacity of heat pump system 2350 W

3. Power supply 220-240/1/50 V/Ph/Hz

4. External static pressure 130Pa

5. Three speed EC motor fan

6. Auto defrosting and bypass central controller

7. The airflow is controlled according to the ambient temperature.

 

The Configeuration

 

1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with heat pump

1. Crossflow heat exchanger                2. Supply fan                   3. Exhaust fan                           4. Fresh air filters

5. Return air filter                                     6. Bypass system         7. Compressors                        8. Evaporator 

9. Condenser                                          10. Connection box       11. Electrical heater                  12. Drain tray

13. Drain pump                                       14. Fresh air vent          15. Exhaust air vent                  16. Return air vent

17. Supply air vent                                  18. Access door             19. Cabinet

 

Dimensions Technicalparameters

1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with heat pump

 

Dimensions Controllerdescription

1200W Electrical heater bypass control Panasonic Compressors with R410a refrigerant ventilator with heat pump

1. The airflow is controlled according to the ambient temperature.

2. Compressor and bypass control

3. The central controller can manage, monitor and control the whole system.
4. Functions of central controller
(1 Timely display of operation data
(2) Timely display of operation status of individual part
(3) Specific check to any data of ay unit
(4) Airflow adjustment according to ambient temperature
(5) Auto defrosting
(6) Auto bypass
(7) Heat pump
(8) Auto restart
(9) Filter monitor
G4: 3 months cleaning reminder
F7: 6 months cleaning reminder
H10: 12 months cleaning reminder
(10) Auto water drain
(11) Alarm
A. Fault alarm of refrigerantion system, high pressure or low pressure alarm
B. Communication failure alarm
C. Frosting alarm
D. Short connection or wrong connect of the sensors
E. Sensors lack or faults alarm
F. Over heating of electrical heater
G. Time resetting after euqipment faults
H. Fire alarm (if return air temperature higher than 45°C.)